Cleanroom & Equipment
Certification Services

Isthmus Env for Madison's cleanroom calibration & certification services.

  • CLEANROOM ISO CERTIFICATION
  • HOOD CALIBRATION & CERTIFICATION 
  • LOCAL MIDWEST SERVICING

CLEANROOM CALIBRATION & CERTIFICATION SERVICES

Isthmus Env, experienced local provider serving Madison, WI and the Midwest. Cleanroom certification, biological safety cabinet certification, hood certification and fume hood testing.

Pharmaceutical & Biotechnology Cleanroom Certification

Following the <USP797/800> standards, our testing includes:

Cleanroom Certification For cGMP Facilities

Following the ISO 14644 standards, our testing includes:

Biological Safety Cabinet (BSC) Certification

Following the NSF49 standards, our testing includes:

Chemical Fume Hood Performance Testing

Following the ASHRAE
standards, our testing includes:

iest
ashrae
ceta
nsf-1
uspImg -update

We Ensure The Highest Quality Of Testing

Our certification testing equipment is annually serviced by the manufacturer for
routine factory cleaning and calibration.

OUR SERVICES

Pharmaceutical & Biotechnology Cleanroom Certification


The test procedures we perform for our pharmacy clients follow the <USP 797/800> standards. This testing includes viable air and surface sampling, particle count testing, HEPA filter integrity testing, visual smoke analysis, ISO Class 5 BSC and LFB certifications, room pressure differentials and air exchange rates.

Cleanroom calibration & certification

Cleanroom Certification For cGMP Facilities


Our cleanroom certification test procedures follow the ISO 14644 standards to determine air cleanliness by particle concentration.This is performed using a light scattering (discrete) airborne particle counter (LSAPC). We document the room pressure differentials between the ISO classified rooms, perform viable air and surface sampling, calculate air exchange rates, test HEPA filter integrity and perform visual smoke analysis.

cleanroom calibration & certification

Biological Safety Cabinet (BSC) Certification


Following the NSF 49 standards, we assure the BSC meets all the primary certification requirements, which include downflow and inflow velocity, HEPA filter integrity test, airflow smoke patterns, as well as UV light intensity and electrical testing. We also offer full service repair including gas decontamination and replacement of motor, HEPA filter and electrical components.

BSC-3in-method-face-velocity, hood certification

Chemical Fumehood Performance Testing


This primary laboratory safety device is critical to workers safety. We not only evaluate the hood itself following ASHRAE standards, but also the lab space the hood is located in. Room cross drafts, face velocity measurements and visual smoke testing, are all analyzed when evaluating the hoods performance.

cleanroom calibration & certification

HERE'S HOW IT WORKS

Convenient, flexible, reliable service. Get started in just 3 simple steps...

Contact Us


We'll discuss your unique business needs and requirements.

Develop a plan


We'll work around your labs schedule to co-ordinate a time that works best for you.

Enjoy


Enjoy the certainty of knowing your business is always in compliance with industry standards.

  • Isthmus Environmental
  • 2858 University Ave 
  • Madison WI 53705